How it works
Four stages, and what each one is for
Stage 01 · replace every 6 months
5 micron polyspun sediment
Rust, silt and sand, caught before they reach the carbon block and the membrane.
Stage 02 · replace every 6 months
5 micron coconut carbon block
Chlorine, taste and odour. This stage also protects the membrane, which chlorine damages.
Stage 03 · replace every 2–4 years
Reverse osmosis membrane
The stage carbon can't do. 50 GPD, roughly 0.0001 micron. Hard water shortens its life, soft water lengthens it.
Stage 04 · replace every 12 months
Dual finishing cartridge — coconut carbon and calcium
Polishes the taste and puts calcium back, bringing the water to a neutral pH of about 7–8.
Installation and servicing
Fitted once by a plumber. Serviced by you after that.
We're straight about this because the difference is where the money is. Getting it installed is a one-off job for a licensed plumber. Keeping it running is not.
-
Your plumber fits it
Mains connection, drain saddle and the benchtop tap. A licensed plumber, once. Budget for it as part of the purchase.
-
You change the cartridges
Twist off, twist on. About two minutes each, by hand, no tools. This is the part people expect to pay for and don't have to.
-
We remind you when
Twelve months on the annual pack. We'll tell you when it's due rather than leaving you to remember.
Up front
$590.00
The system, the tank and the tap. Plus your plumber's fee for the one-time install, which we don't charge and can't quote for you.
Every year after
$77.00
One pack, changed by you. Membranes last longer than a year, so occasionally the full pack is the one you want instead.
Annual 4 Stage RO Replacement Pack - PH Neutral System - Standard 10"Detail
Specifications
| Model | GT1-26-4SCC |
|---|---|
| Stages | 4 — sediment, carbon block, RO membrane, calcium finishing cartridge |
| Membrane | Asprinn 50 GPD (190 L/day), approx. 0.0001 micron |
| Production rate | approx. 8 L/hour |
| Finished water pH | approximately 7–8 |
| Minimum inlet pressure | 350 kPa — see the note below |
| Maximum inlet pressure | 700 kPa, with a pressure limiting valve set to 500 kPa required |
| Feed water | Town / mains · TDS 0–2,000 mg/L · iron under 0.02 mg/L · manganese under 0.1 mg/L · hardness under 500 mg/L |
| System dimensions | 39cm H × 37cm W × 21cm D |
| Tank dimensions | 41cm high with stand, 38.5cm without · 27cm wide |
| Cartridge change | Standard 10" × 2.5" housings — not quick change |
| Installation | By a licensed plumber, to comply with Australian plumbing codes |
| Warranty | 12 months against defects, excluding consumables |
Required for anything connected to mains water in Australia. This is a range certificate and it does cover this system. The RO membrane element is separately stated as certified to NSF/ANSI 58 for TDS reduction.
Specifications from the manufacturer's listing and manual for GT1-26-4SCC. The listing states 350 kPa minimum inlet pressure; the installation manual for the same system states 400 kPa. If your pressure sits between the two, check with us before ordering — it affects how well the membrane performs.